Version 2.23.3 of SHOTPlus™ Tunnel, first offered to users on Tuesday, 8th July 2025.
A notification will appear on start-up in SHOTPlus™ Tunnel once the update is available.
For further information on updating SHOTPlus™, please contact the BlastIQ™ Support Team via support.blastiq.com.
Important
Update to SHOTPlus™ Tunnel Support Policy
There has been an update to the support policy for SHOTPlus™ Tunnel. Support will be provided for the current version, with a buffer of 60 days for the previous version to allow time to update.
For more information on this update, please refer to this article.
New
- Users will no longer able to license SHOTPlus™ Tunnel with product keys.
- "Hole Type Names" are now able to be exported via text export.
- "Decking mode" in the eDev™ timing tool is no longer supported .1
- A new GUID parameter is generated each time File > Export > All MDCU charge files is run support changes to the WebGen™ workflow.2
- Users can now export local collar coordinates via Text Export.
- There are now two volume calculations in Calculations > Performance Indicators:
- "Blast volume" is the profile cross-section area multiplied by the hole length.
- "Blast volume (hole based)" is the sum of the calculated volume per hole.
Information
- "Decking mode" was a specialised tool used for a specific use case in civil tunneling. Users are still able to use eDev™ in holes with multiple decks without "Decking mode".
- The GUID will be made available to copy from the confirmation dialog box once file export is complete. A new code is generated each time the MDCU files are created. Users can check the current GUID via "Blast header information" in Blast Properties.
Improved
- The old print functionality has been retired as part of the SHOTPlus print standardization across the SHOTPlus suite. 1
- In 'Program Settings,' >'BlastIQ™ Online Settings', is now renamed to 'NCVIB Server' to more accurately describe the pane's function.
- The "Void" hole type now accurately displays the hole diameter in the main window.
- Improved messaging for timing decked holes using eDev™.
- When using the eDev™ tool, holes with multiple decks and detonators are being counted correctly.
- Users exporting files for MDCU charge plans can now use an ejection charge > 0.2kg.
- Increased range of hole angles:
- In Horizontal/Vertical mode: the horizontal and vertical angles are valid within the range (-80°, 80°).2
- In Angle/Bearing mode: the angle values are valid within the range (0°, 80°).
Information
- For further information about the new print functionality please refer to the KBA.
- When an angle is greater than 80° approaching 90°, the mathematical calculations exceed the limits of the model.
Fixed
- The 'Remove Timing' function in the Tools > Holes menu, now re-named 'Remove in-hole initiation', was not operating as designed.
- Dimension text labels now align with the plan view during printing.
- The "Retain existing timing function", was not performing after loading design was emptied and reapplied.
- The Cut Tool template editor now applies EBS timing and displays the EBS toolbar correctly.
- The 'Edit Template' and 'Delete Template' options in the Cut Tool template window now function correctly upon template import.
- The Hole tool now reflects the applied program unit settings.
- Summary block was not printing properly.
- Deleted profiles were appearing the Project Overview tool.
- Main window refresh was delayed when hole type colours were changed.
- When importing a cut template, all objects will now be stored in the "Cut" layer.
- SHOTPlus™ Tunnel was not importing as-drilled holes correctly.
- SHOTPlus™ Tunnel was incorrectly counting the number of as-drilled holes in Project Overview.
- Deleting a cut template from a project was causing an error.
- When using the Dimension tool in the Cut Editor, dimension objects were not automatically being stored in the Dimension layer.
- SHOTPlus™ Tunnel was not allowing users to create blasted sections using a DXF.