The next-generation user interface for all automotive USB PC Oscilloscopes, including all the analysis tools you need to get answers quickly, whether carrying out a simple test, or debugging a complex design.
NOTE: From this version, PS7 will no longer install on MS Windows 7, 8, 8.1 and the earliest release versions of 10.
A new Channel Deskew control has been integrated into the Channel Display tabs.
A new Waveform Overlay tool allows multiple scope or spectrum traces to be overlaid using controls in the Waveform Navigator, enabling range selection to identify anomalies or visualize changes over time.
The amplitude strategy (Top/Base or Peak-to-Peak) can now be selected for Rise/Fall Time and Rise/Fall Rate measurements and math channels.
Measurements can now be selected or deselected to show or hide their graph indicators, with only one measurements indicators displayed at a time. This is currently supported for Pk-Pk, Min, Max, Edge Count, Cycle Time, Frequency, Pulse Width, Rise/Fall Time, Rise/Fall Rate, RMS, RMS ripple, Top/Base, Amplitude, Mean, Phase, Delay, Duty Cycle, Overshoot and Crest Factor measurements. The feature can be enabled or disabled in Add Measurement > Settings.
Serial decoder filters now display the filtered data on the graph.
Serial decoding filter settings are now saved within .psdata and .pssettings files.
Added an isoSPI decoder to Serial Decoding.
Actions can now be configured to trigger when a measurement passes or fails its limit, either for specific measurements or across all added measurements.
Ruler values are now included in printouts, when printing to PDF and when copying as image.
Phase rulers can now be locked together when moving them.
Ruler delta and tracking ruler values can now be selected and copied.
Waveform capture times can now be exported to a CSV file via the Waveform Navigator and Save dialog.
A new tool button has been added to return to factory settings, alongside the existing Reset Configuration control, which restores settings from the start of the session (Factory, User-defined, or Last Session settings).
Measurements, Notes and Ruler information is now appended when saving as PNG.
Spectrum view data can now be exported to the Matlab file format.
Reference waveform delay adjustment has been improved to cover the entire current capture time.
Setup Wizard has been added to the top toolbar for quick access.
Numeric values can now be fine-adjusted by holding the SHIFT key while using the + / - buttons or mouse wheel.
Some translations updates.
Bug fixes
Resolved an issue where the trace could flicker when zooming in Persistence mode.
Spectrum views now update correctly when the number of bins is changed after stopping a capture.
Resolved an issue where the Start Up/Down control in Spectrum skipped a value when clicking the - button.
Resolved an issue when exporting serial decoded data in ODS file format.
Fixed an issue in which Serial Decoding settings were not saved when channels were disabled and re-enabled.
Resolved an issue where Auto Range did not function with overranged input when a linear probe was in use.
Improvements to edge count measurement stability.
Resolved an issue where only a single buffer could be captured in certain situations.
Various timestamp-related fixes have been implemented.
Improvements have been made to address slow or unresponsive rulers when used with math channels and large datasets.
Saving user default .pssettings files no longer causes subsequent customer data file saves to default to AppData\Local\Pico Technology.
Fixed a hang when trying to export large captures with maths channels to csv.
Resolved an issue when loading files containing serial decoded data saved in older PS7 versions.
Fixed a software hang that occurred during the export of large captures containing math channels to CSV format.
Resolved an issue where actions triggered by a mask limit test results could become unsynchronized.
Resolved an issue where the "Stop Capture" action in Actions would not trigger in certain situations.
Resolved an issue where part of the trace could temporarily disappear when zooming with multiple viewports.
Tabbed viewports now display graphs correctly when loading files.
Resolved an issue that made graph adornments difficult to move when using touch controls.
Some general performance optimisations when opening the Save dialog, when using the Waveform Navigator and after capturing with Rapid trigger.
General stability fixes have been applied.
[Toolbox] PicoScope 7 and Toolbox are now aligned, allowing selection of engine capacities up to 150 litres.
[Toolbox] The Maximise button no longer closes Toolbox.
[PicoDiagnostics] Compression test translation has been fixed for Italian.
[PicoDiagnostics] Resolved an issue where road speed vibration orders were displayed incorrectly.
[PicoDiagnostics] Resolved an issue where RP1210 devices were not displaying the port.
[PicoDiagnostics] Resolved an issue where the crash reporter was not displayed when PicoDiagnostics crashed.
[PicoDiagnostics] Resolved an issue with ELM327 connections.